(8) Stations of load & unload available. The 7’ 3”
deep tanks allow operators to work safely below
hoists’ operating/transfer level.
Exhausted tanks have pneumatic tank covers to
minimize exhaust and heated make-up air |
Special spray rinsing systems using high pressure pumps and 5-station, off-line counter-flow rinses.
System was used for alkaline zinc, with off-line zinc regeneration system, with robust polypro zinc tanks, and can be adapted for acid, chloride zinc. |